Stryker 1588 Camera System for ENV Mode

AA Medical Store is committed to educating and updating our current and future customers to ensure their patients have the highest level of care they deserve.

The Stryker 1588 AIM (Advanced Image Modality) camera system allows surgeons to visualize anatomy and blood flow during a variety of minimally invasive and open procedures. The high-definition camera system is designed to help distinguish critical anatomy with multiple dedicated surgical imaging modes, including ENV (Endoscopic Near Infrared Visualization).  

ENV mode enhances visualization of anatomy in real-time during surgery. When this mode is activated, it allows surgeons to visually assess blood flow, tissue perfusion and biliary ducts by using fluorescent light. ENV is used with a fluorescent indocyanine green (ICG) dye.

It is a common misconception that all you need is a Stryker 1588 AIM camera control unit for ENV mode to be activated during surgery. There are a few other medical devices that must accompany the 1588 AIM camera control unit for ENV mode to work:

  • L10 LED AIM Light Source—provides real-time endoscopic visibility and near-infrared fluorescence imaging. This light source will connect to the 1588 AIM Camera Control Unit.
    • Part Number:
      • 220-220-300
  • A-to-A USB Cable—this cord will connect the 1588 AIM Camera Control Unit to the L10 LED Light Source w/ AIM box. AA Medical Store will provide this cord. 
  • Stryker Fiber Optic Cable—plugs into the L10 LED AIM light source. The other end of the Fiber Optic cable will plug into the adapter on the laparoscope. It is a mistaken belief that for ENV mode to work, a green Stryker Fiber Optic cable must be used. This is NOT TRUE! Multiple light cables will work and still allow ENV mode to be activated.
    • Part Numbers:
      • 233-050-100
      • 233-050-200
      • 233-050-300
  • Stryker 1588 Camera Head—plugs into the front of the 1588 AIM camera control unit.
    • Camera Head Part Numbers:
      • 1588-210-105
      • 1588-610-122 (Integrated Camera Head with Coupler)
  • Stryker 1588 Coupler—connects to camera head 
    • Coupler Part Number:
      • 1588-020-122
  • Stryker Safelight Henke/Dyonics/Storz Scope Adapter—connects to scope and fiber optic light cable.
    • Part Number:
      • 233-050-087
  • Stryker 10.0 mm 0° or 30° Autoclavable Laparoscope/Stryker 5.0 mm 0°, 30°, or 45° Autoclavable Laparoscope—these Stryker AIM scopes are needed for ENV mode to be activated.
    • Part Numbers:
      • 502-937-010
      • 502-937-030
      • 502-537-010
      • 502-537-030
      • 502-537-045

 

Stryker Endoscopy. 1588 AIM SPY Fluorescence Technology. Retrieved March 2020, from https://www.stryker.com/us/en/endoscopy/systems/aim-platform.html